Thursday 16 February 2012

ORA-12047: PCT FAST REFRESH cannot be used for materialized view string. string

ORA-12047: PCT FAST REFRESH cannot be used for materialized view string. string

Cause: PCT refresh is either not enabled on this materialized view or not possible after set of the base table changes since last refresh.

Action: Use just REFRESH FORCE, which will reinstantiate the entire table and try to pick the best refresh method on the materialized view Do explain_mview to look at the cause why PCT refresh is not possible on this materialized view

No comments:

Post a Comment